Safety data sheet. GHS / OSHA HCS 2012 format, 16 sections. Issued by Epic Peptides Lab for the catalogue items listed in Section 1.

Epic Peptides Lab

Safety data sheet · lyophilized powder, vial

Epic Peptides Lab · USA

Document number
PL-SDS-131
Revision
1.0 · 2026-10-03

PNC-27

lyophilized powder, vial

1Identification

Product Identifier
PNC-27
Document Number
PL-SDS-131
Catalogue Items Covered
  • Id
    16659
    Name
    PNC-27 10mg
    Sku
    PL-PNC27-10MG-VIAL
  • Id
    16653
    Name
    PNC-27 5mg
    Sku
    PL-PNC27-5MG-VIAL
Recommended Use
Laboratory research use by trained personnel.
Restrictions On Use
Not for human or veterinary use.
Supplier / Distributor
Epic Peptides Lab, USA
Telephone
+1 (787) 468-5291
Email
info@epicpeptideslab.com

2Hazard(s) identification

Classification
Not classified as hazardous under OSHA HCS 2012 (29 CFR 1910.1200) or UN GHS, on the basis of the supplier safety data sheets consulted.
Label Elements
No data available.
Signal Word
No data available.
Other Hazards
No data available.

3Composition / information on ingredients

Description
Lyophilized (freeze-dried) powder or cake in a sealed glass vial with a rubber stopper and aluminium crimp cap.
Composition
  • Name
    PNC-27
    Full
    p53(12–26) fused to a membrane-residency peptide
    Cas
    1159861-00-3
    Formula
    C188H293N53O44S
    Conc
    ≥ 95% (dry basis, as supplied)
    Qty
    5 mg, 10 mg per vial

4First-aid measures

First Aid Measures
Inhalation
Move the person to fresh air and keep comfortable for breathing. If breathing is difficult or symptoms persist, call a POISON CENTER or doctor.
Skin
Take off contaminated clothing. Wash the skin with plenty of soap and water. If irritation or a rash develops, get medical advice.
Eyes
Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do; continue rinsing. If eye irritation persists, get medical advice.
Ingestion
Rinse mouth. Do not induce vomiting. Call a POISON CENTER or doctor if you feel unwell.
Most Important Symptoms And Effects
No specific symptoms are known. Pharmacologically active material: systemic effects consistent with its mechanism of action are possible after accidental injection, ingestion or absorption.
Likely Routes Of Exposure
Inhalation of dust, skin and eye contact when the vial is opened or the powder is weighed; ingestion through contaminated hands; accidental injection when reconstituted solutions are drawn into syringes.

5Fire-fighting measures

Fire Fighting Information
Combustible organic solid; finely divided powder may form dust clouds. Not flammable in the quantities supplied.

6Accidental release measures

Spill And Clean Up Procedures
Avoid dust formation. Dampen spilled powder with water, wipe up with absorbent material, place in a sealed container for disposal and clean the area with water and detergent.

7Handling and storage

Safe Handling
Open vials only in a clean area. Avoid generating or inhaling dust; weigh or reconstitute inside a ventilated enclosure when the full contents are handled as a dry powder. Reconstitute by adding diluent slowly to the vial wall; do not shake. Wash hands after handling.
Safe Storage
Store the sealed vial at the temperature stated in Section 9 (typically −20 °C for peptides, 2–8 °C for proteins), desiccated and protected from light. Allow the vial to reach room temperature before opening to avoid condensation. Reconstituted solutions: 2–8 °C, protected from light; use within the period established by your laboratory.
Storage Temperature
−20 °C (sealed vial), desiccated and protected from light; 2–8 °C acceptable for short periods
Incompatible Materials
Heat and moisture

8Exposure controls / personal protection

Occupational Exposure Limits
No data available.
Exposure Controls And PPE
No data available.

9Physical and chemical properties

Physical State
Solid
Appearance
White to off-white lyophilized powder
Properties
Odor
Little to none
Ph
Not applicable (solid); aqueous solutions typically pH 4–7
Melting
Not available
Boiling
Not available
Flash
Not applicable (non-flammable solid); combustible organic material
Vapour
Negligible (solid)
Density
No data available (bulk density of lyophilized cake is low)
Solubility
Reconstitute in sterile water at >= 100 ug/mL (ProSpec); soluble in water
Logp
Not available
Decomp
No data available; peptides decompose above about 200 °C
Other
32-residue peptide, C188H293N53O44S, MW 4031.7; sequence PPLSQETFSDLWKLLKKWKMRRNQFWVKVQRG; lyophilized with no additives (ProSpec)

10Stability and reactivity

Stability And Reactivity
Reactivity
Stable under recommended transport and storage conditions
Incompatible
Heat and moisture; strong acids/alkalis; strong oxidizing/reducing agents
Decomposition
In combustion may emit toxic fumes (carbon oxides, nitrogen oxides, sulfur oxides)
Conditions To Avoid
Heat, moisture, repeated freeze-thaw; store desiccated below -18 C
Conditions To Avoid
Heat, moisture, repeated freeze-thaw; store desiccated below -18 C
Incompatible Materials
Heat and moisture

11Toxicological information

Toxicological Information
  • Acute toxicity, oral

    No data available

  • Acute toxicity, dermal

    No data available

  • Acute toxicity, inhalation

    No data available

  • Skin corrosion/irritation

    No data available

  • Serious eye damage/irritation

    No data available

  • Respiratory or skin sensitisation

    No data available

  • Germ cell mutagenicity

    No data available

  • Carcinogenicity

    No data available; not listed by IARC

  • Reproductive toxicity

    No data available

  • STOT, single exposure

    No data available

  • STOT, repeated exposure

    No data available

  • Aspiration hazard

    No data available

Routes Of Exposure
Inhalation of dust, skin and eye contact when the vial is opened or the powder is weighed; ingestion through contaminated hands; accidental injection when reconstituted solutions are drawn into syringes.
Symptoms
No specific symptoms are known. Pharmacologically active material: systemic effects consistent with its mechanism of action are possible after accidental injection, ingestion or absorption.

12Ecological information

Ecological Information
No ecotoxicity, biodegradability, bioaccumulation or soil-mobility data (ProSpec).

13Disposal considerations

Disposal Guidance
No data available.

14Transport information

Transport Classification
Note
Not regulated as a dangerous good for transport by road (DOT 49 CFR), air (IATA/ICAO) or sea (IMDG). Not a marine pollutant. Ship refrigerated or frozen as required by Section 7; the coolant (dry ice, UN 1845) is regulated when used.

15Regulatory information

Regulatory Information
Tsca
Not applicable / not listed
Carcinogen Listings
None
Dea
Not a controlled substance
Other
SARA 313/311/312, CERCLA, Prop 65: not applicable. Transport: non-hazardous. Not WADA prohibited.
Carcinogen Listings
No data available.

16Other information

Revision
October 3, 2026
Sources Consulted
  • ProSpec-Tany TechnoGene
  • MedChemExpress
  • ChemicalBook
Confidence
medium
Additional Information
  • Lyophilised synthetic 32-residue peptide. Inhalation of protein dusts can sensitise susceptible individuals; avoid generating dust and handle the dry powder in a ventilated enclosure. Not classified for respiratory sensitisation because no substance-specific data exist.
Back to SDS list
JOIN THE Epic Peptides Lab
Exclusive access for verified researchers only.

Enter your details to access our catalog, COA library,
and research compound database.

By submitting you agree to receive email communications from Epic Peptides Lab You can unsubscribe at any time. All products for in vitro research use only.

15% off any order

Restock alerts, new compounds and fresh lab results.
We’ll email your code straight away – 15% off, one-time use.

Research updates only. Unsubscribe any time.